Skip to main content
  • Original research article
  • Open access
  • Published:

Identification alone versus intraoperative neuromonitoring of the recurrent laryngeal nerve during thyroid surgery: experience of 2034 consecutive patients

Abstract

Background

The aim of this study was to evaluate the ability of intraoperative neuromonitoring in reducing the postoperative recurrent laryngeal nerve palsy rate by a comparison between patients submitted to thyroidectomy with intraoperative neuromonitoring and with routine identification alone.

Methods

Between June 2007 and December 2012, 2034 consecutive patients underwent thyroidectomy by a single surgical team. We compared patients who have had neuromonitoring and patients who have undergone surgery with nerve visualization alone. Patients in which neuromonitoring was not utilized (Group A) were 993, patients in which was utilized (group B) were 1041.

Results

In group A 28 recurrent laryngeal nerve injuries were observed (2.82%), 21 (2.11%) transient and 7 (0.7%) permanent. In group B 23 recurrent laryngeal nerve injuries were observed (2.21%), in 17 cases (1.63%) transient and in 6 (0.58%) permanent. Differences were not statistically significative.

Conclusions

Visual nerve identification remains the gold standard of recurrent laryngeal nerve management in thyroid surgery. Neuromonitoring helps to identify the nerve, in particular in difficult cases, but it did not decrease nerve injuries compared with visualization alone. Future studies are warranted to evaluate the benefit of intraoperative neuromonitoring in thyroidectomy, especially in conditions in which the recurrent nerve is at high risk of injury.

Background

Operation on the thyroid gland are the most frequently performed endocrine procedures worldwide. Improvements in technique have decreased the risk of injury to adjacent structures to minimal levels [1]. Apart from hypoparathyroidism [2, 3] and hematoma [3, 4], recurrent laryngeal nerve palsy is the most common and serious complication after thyroid surgery [2, 3, 5, 6] and it is the leading cause of medicolegal litigation after endocrine surgery [2, 3, 7].

The rate of recurrent laryngeal nerve palsy varies from 0.5 to 20% depending on the type of disease (benign or malignant), the type of surgery (first time or reoperation), the extent of resection, and the surgical technique [5, 6, 814]; abnormal anatomy, bulky disease and surgeon inexperience are additional risk factors of recurrent laryngeal nerve injury [3, 6, 8, 1517].

Recurrent laryngeal nerve injury can diminish quality of life due to a variety of symptoms related to voice changes and subsequent limitations in physical, emotional and social functioning, while bilateral injury can be a life-threatening complication leading to airway obstruction [6, 18, 19].

Intraoperative identification of the recurrent laryngeal nerve has been demonstrated to decrease the incidence of postoperative nerve palsy [57, 15, 18, 20, 21]. But even in the most experienced hands recurrent laryngeal nerve palsy occurs occasionally, with permanent palsy rate of 1-2% and temporary palsy rate of up to 5-6%, owing to variability in nerve anatomy and difficulties in nerve identification [2, 5, 15, 2226].

The causes of recurrent laryngeal nerve injury could result from transaction, clamping, stretching, electro-thermal injury, ligature entrapment, or ischemia [24, 2730]; several studies have reported that anatomical variations of the recurrent laryngeal nerve, such as extralaryngeal branches, distorted recurrent laryngeal nerve, intertwining between branches of the recurrent laryngeal nerve and inferior thyroid artery and non-recurrent laryngeal nerve, play an important role in the occurrence of nerve injury that can be caused by visual misidentification [24].

In recent years, increasing attention has been paid to the use of neuromonitoring devices to reduce the risk of nerve injury during thyroid surgery [15, 31]. Many studies reported a high negative predictive value of 92-100% but a low and highly variable positive predictive value of 10-90% [2, 32]. Recurrent laryngeal nerve monitoring is being used with increasing frequency in the United States during thyroidectomy, partly driven by the medico-legal system [10, 22, 3335] while German surgeons use the method routinely even much more often than the Americans [1]; the rates of the use of neuromonitoring have recently become almost equivalent between general surgery- and otolaryngology-trained surgeons [14, 22, 36]. However, the use of recurrent laryngeal nerve monitoring is associated with increased time of setup and increased cost of equipment by about 5-7% [1, 33]. The economic impact is considerable, owing to the costs of the technology, which, for the entire equipment set-up, could vary from 15,000 to 20,000 Euro [25, 37].

The aim of the present retrospective study was to evaluate the ability of this technique to predict the postoperative functional outcome and the role of intraoperative neuromonitoring in reducing the postoperative recurrent laryngeal nerve palsy rate by a comparison between patients submitted to thyroidectomy with intraoperative neuromonitoring and with routine identification alone in a single endocrine surgical centre.

Methods

Between June 2007 and December 2012, 2034 consecutive patients underwent thyroidectomy by a single surgical team. 1749 patients were submitted to total thyroidectomy, 231 to total thyroidectomy with VI level lymphectomy, and 54 underwent completion total thyroidectomy. 1615 were female and 419 male with a mean age of 51 years (range 15–87 years).

The final diagnosis were: in 751 cases multinodular goiter (36.9%), in 615 differentiated carcinoma (30.2%), in 424 Hashimoto’s thyroiditis (20.8%), in 215 Graves’ disease (10.6%), in 29 medullary carcinoma (1.4%).

Histological diagnosis and surgical procedures are summarized in Table 1.

Table 1 Histological diagnosis and surgical procedures

In differentiated carcinoma, lymph node metastasis were found in 49 patients (7.6%) and micrometastasis in 14 (2.21%). Totally lymph node metastasis were observed in 61 patients (9.47%).

The study was approved by the Bioethics Commitee of the University of Cagliari. All patients provided written informed consent for the intervention and for the storage and use of their data.

All operations were performed by three experienced endocrine surgeons, with a standard Kocher’s incision. All patients were submitted to preoperative and postoperative laryngoscopy. Post-operative laryngoscopy was performed 2 days after the surgical procedure.

The recurrent laryngeal nerves were routinely identified by visualization and completely exposed. In 1711/2034 operations the relation between nerves and inferior thyroid artery and its branches was described.

Recurrent laryngeal nerves were posterior to inferior thyroid artery in 85.44% of cases on the right side and 82.81% on the left. Nerves were anterior in 5.4% of cases on the right and 5.01% of cases on the left. Nerves with extralaryngeal bifurcation were 2.38% on the right and 2.3% on the left, whilst course of the nerve between the branches of the artery was found in 5.78% on the right and 5.21% on the left. In 1% of cases a non recurrent nerve or a nerve with an extralaryngeal trifurcation was found.

Intraoperative neuromonitoring was performed in 1041 patients on the basis of the availability of the equipment (2068 nerves at risk). All these patients undergone general anesthesia and were intubated with Nerve Integrity Monitor Standard Reinforced Electromiography Endotracheal Tube (Medtronic Xomed). The tube was placed with the middle of the blue-marked region (3 cm of the exposed electrodes) well in contact with the true vocal cords under direct laryngoscopy. When the monitor was well set up, we routinely checked the impedance of electrodes. A Prass monopolar stimulation probe (Medtronic Xomed) was used for nerve stimulation during thyroidectomy. EMG activity was recorded on a NIM-response 2.0 or 3.0 monitor (Medtronic Xomed). No muscle relaxants were used after the skin flaps were elevated.

The neuromonitoring device was used in various phases of the operation: at the beginning, a stimulation was done to the level corresponding to the vagus nerve to ensure that the monitoring system was working; after, to the structure believed to be the inferior laryngeal nerve; at the end, to the level of both the vagus and the recurrent nerve after the removal of thyroid and the hemostasis of the surgical field for predicting the postoperative outcome.

Patients in which the nerve monitoring did not function properly were excluded from the study.

We compared patients who have had neuromonitoring and patients who have undergone surgery with nerve visualization alone.

Patients in which neuromonitoring was not utilized (Group A) were 993 (1946 nerves at risk), 169 male and 824 female. 854 (86%) were submitted to total thyroidectomy, 40 (4.03%) to completion total thyroidectomy and 99 (9.97%) to a total thyroidectomy associated to a VI level lymphectomy. In this group diagnosis was benign multinodular goiter in 374 (37.66%) patients, differentiated carcinoma in 285 (28.7%), Hashimoto’s thyroiditis in 216 (21.75%), Graves’ disease in 104 (10.47%), medullary carcinoma in 14 (1.41%).

Patients in which neuromonitoring was utilized (group B) were 1041 (2068 nerves at risk), 250 male and 791 female. 895 (85.98%) were submitted to a total thyroidectomy, 14 (1.34%) to a completion total thyroidectomy and 132 (12.68%) to a total thyroidectomy associated to a VI level lymphectomy. In this group diagnosis was benign multinodular goiter in 377 (36.22%) patients, differentiated carcinoma in 330 (31.7%), Hashimoto’s thyroiditis in 208 (19.98%), Graves’ disease in 111 (10.66%), medullary carcinoma in 15 (1.44%).

Groups were homogeneous for characteristics of patients, diagnosis and type of surgery.

We define "transient" an injury in which the motility of the vocal cords recovered within 12 months after surgery.

Parameters were tested using the chi-square test. A logistic regression analysis was fitted using transient and permanent palsy as measurements of outcome. A p value of less than 0.05 was considered to be significant. Statistical analysis was done with SPSS software (SPSS in, Chicago, III).

Results

In group A 26 unilateral recurrent laryngeal nerve paralysis were observed (2.62%) of which 20 (2.01%) transient and 6 permanent (0.6%). Bilateral palsy was observed in 2 cases (0.2%); in one patient a vocal cord recovered completely three months after surgery. The patient, which has had a completion thyroidectomy, had a nerve unilateral palsy by previous surgery. In the other case, the patient required a tracheostomy and the lesion was permanent. Totally in group A 28 recurrent laryngeal nerve injuries were observed (2.82%), 21 (2.11%) transient and 7 (0.7%) permanent.

In group B 21 unilateral recurrent laryngeal nerve paralysis were observed (2.02%), 15 (1.44%) transient and 6 (0.57%) permanent. In this group of patients a bilateral recurrent laryngeal palsy was observed in two cases (0.19%) requiring a tracheostomy. Totally in group B 23 recurrent laryngeal nerve injuries were observed (2.21%), in 17 cases (1.63%) transient and in 6 (0.58%) permanent. Differences between the two groups were not statistically significative (Table 2).

Table 2 Recurrent laryngeal nerve paralysis in the two groups in relation to type of surgery and histology

The mean postoperative hospital stay was 2 days in both groups.

In group B we had 21 true positive cases, 1012 true negative, 6 false positive and 2 false negative. Accuracy of neuromonitoring was 99.2%, positive predictive value 77.8%, negative predictive value 99.8%. Sensitivity was 91.3% and specificity 99.4% (Table 3).

Table 3 Correlation of neuromonitoring results with postoperative outcomes

Recurrent laryngeal nerve paralysis in the two groups in relation to type of surgery and histology are reported in Table 2. Differences were not statistically significant.

No complications were attributable to the use of intraoperative neuromonitoring.

Discussion

The incidence of recurrent laryngeal nerve palsy varies from less than 1% to as high as 20% [26, 32, 38]. Several factors influence the likelihood of nerve injury, including the underlying disease, the extent of resection, and the experience of the surgeon [16, 17, 39]; substernal goiters and reoperative thyroid procedures have a higher rate of complications because of scarring and loss of normal tissue planes [32, 4042]. Even experienced surgeons report inadvertent injury to the nerve and persistent palsy in about 1-2% of patients [32, 38, 39, 43]. The reported causes of recurrent laryngeal nerve injury result from damage to the nerve’s anatomic integrity, thermal lesions, excessive nerve skeletization, axon damage caused by excessive strain, edema, hematoma, difficult tracheal intubation, and neuritis [44]; but the actual causes of recurrent laryngeal nerve injury, especially in those with visual integrity, are still not well understood [27]. Several studies have shown that surgeons were not aware of nerve injury during the operation in most instances [27].

Visual identification of recurrent laryngeal nerve during thyroid operations has been associated with lower rates of permanent recurrent laryngeal nerve palsy and is considered the gold standard of recurrent laryngeal nerve treatment by many studies [27]. In 1938 Lahey first dissected the recurrent laryngeal nerve in virtually every case; careful dissection decreased the number of injuries to the recurrent nerves and this approach is accepted by most endocrine surgeons [26]. Nerve identification in certain types of operations may be very difficult: these difficult cases include reoperations, surgery for malignant disease, anatomic variants, and a history of irradiation or inflammation [16, 26, 45]. Nerve monitoring has been developed to facilitate the identification of the recurrent laryngeal nerve during thyroid surgery [18, 23, 26, 45] and it may provide guidance for the surgeon in such difficult situations [45].

There are a wide variety of techniques for nerve monitoring but the most common method in current use is a special endotracheal tube with electrodes embedded on it that register effects of stimulation in the vocal cords [25, 46]. Despite the increasing popularity of this technology, its impact in the avoidance of nerve injury and the reduction of the incidence of postoperative nerve palsy remain doubtful [23, 25].

Several non-randomised studies demonstrated that an improved intraoperative recurrent laryngeal nerve identification rate with neuromonitoring resulted in lower palsy rates than in historical patient cohorts with identification alone [19]. The largest non-randomized multicenter trial conducted in Germany with more than 16,000 patients reported that the device could help in decreasing the risk of nerve injury [13, 19, 46].

A large multicentre study of 4382 patients found a statistically significant reduction in rates of transient and permanent recurrent laryngeal nerve paralysis with the use of intraoperative nerve monitoring in surgery for benign goiter; subgroup analysis of the same study found higher rates of injury when intraoperative nerve monitoring was used for total thyroidectomy [19, 25].

On the other side, a large single-centre study of 1000 consecutive nerve at risk found that continuous nerve monitoring offered absolutely no benefit in reducing the risk of nerve injury compared with the adoption of routine nerve identification, with no difference in both the temporary and the permanent nerve injury rates [23, 25].

In the study of Dralle [6] intraoperative nerve monitoring did not lower the risk of nerve injury although failure to visually identify the nerve was associated with a higher rate of injury; nerve injury rates were also higher for low-volume hospitals and low-volume surgeons and this fact was confirmed by others [5, 23, 26, 33].

In the meta-analysis of Higgins [47], intraoperative neuromonitoring and identification alone did not demonstrate a statistically significant difference in rates of total, transient, or persistent true vocal fold palsy with adequately-powered sample sizes for all thyroid surgeries, primary surgery, benign disease, and low-risk groups.

Other studies claim that the nerve monitoring is really of value only in high-risk surgery, re-operative cases, or recurrent goiters [25, 33], but an impractically large number of patients would be needed because of the rarity of nerve injury that is achieved in specialized centers [23].

In a prospective, randomized study of 1,000 patients (1,000 nerves at risk for each group), the prevalence of transient recurrent laryngeal nerve palsy was significantly lower in the group of patients who had surgery with intraoperative neuromonitoring by 2.9% in high-risk patients and 0.9% in low-risk patients [5, 48]. The rate of permanent nerve palsy tended to be lower in operations performed with intraoperative neuromonitoring (by 30%), but the power of this study was not sufficient to validate this difference [5].

In our study the rates of postoperative recurrent laryngeal nerve paralysis did not differ significantly between the two groups. The rate of transient and definitive recurrent laryngeal nerve paralysis were 2.11% and 0.7% respectively in group A (visualization alone) and 1.63% and 0.58% in group B (with neuromonitoring); this slight difference showed no statistical significance. No statistically significant difference in the rate of vocal cord paralysis was found in relation to the most common histological diagnosis. The main weakness with this and other studies on this topic is just the inadequate power to identify a statistical difference and this is a significant limitation. The patients were not randomized which could lead to bias, but the number of patients is very large (2034, 4014 nerves at risk) and the groups are very well matched. To our knowledge, this is the largest mono-institutional study published in the literature to date. Our opinion is that neuromonitoring can help in the nerve identification particularly in difficult situation such as reoperative surgery or anatomic variations but it is very difficult to demonstrate a statistically significant reduction in the incidence of injuries because an extremely large number of patients would be needed. However it must be said that difficult situations are not always predictable preoperatively.

It has been observed that an anatomically intact nerve does not always correlate with normal vocal fold function and that the absence of signal does not necessarily imply nerve dysfunction [33].

In the study of Thomusch [19] a normal intraoperative neuromonitoring signal certainly excluded postoperative vocal cord dysfunction. Indirect stimulation of the recurrent laryngeal nerve via the vagus nerve was a significantly better predictor of postoperative dysfunction than direct stimulation and should be always performed to monitor the axonal excitability and mechanical intactness of the nerve. Direct nerve stimulation is exclusively recommended to detect the recurrent laryngeal nerve anatomy. After indirect nerve stimulation and a normal intraoperative neuromonitoring signal, the surgeon can extend the operation to the contralateral side, being reassured that the nerve on the resected side has a 99.6% chance of being intact [19].

In some cases an absent or abnormal intraoperative neuromonitoring signal failed to predict reliably a postoperative palsy. This failure may be due to problems with the technical device, wrong application or continuous relaxation during the operation with paralysed vocal musculature, resulting in an absent signal. An absent or abnormal signal was a rare phenomenon, with an incidence of 2.7% after indirect recurrent laryngeal nerve stimulation, and in these cases, 29.8-45.9% of the patients had postoperative vocal cord dysfunction [19].

Our experience confirm the high accuracy (99.23%), sensitivity (91.3%) and specificity (99.41%) of this method; positive predictive value was 77.77% and negative predictive value 99.8% confirming the data reported in the literature.

The use of these devices in thyroid surgery seems to be more expensive than the conventional technique. This is probably the major disadvantage [26] and particularly for this reason routine nerve monitoring is no cost-effective [25].

The proponents of routine nerve monitoring claim that its use can still be justified for bilateral surgery stating that if nerve monitoring is undertaken after completion of one side of the procedure and there is evidence of impaired function, then the procedure should be abandoned to avoid the risk of bilateral damage [5, 18, 19, 25, 45]. A failed intraoperative neuromonitoring stimulation of the recurrent laryngeal nerve after resection of the first lobe is specific enough to reconsider the surgical strategy in patients with bilateral thyroid disease to surely prevent bilateral recurrent laryngeal palsy [49].

Neuromonitoring provides comfort during thyroidectomy for identification, dissection, and control of recurrent laryngeal nerves; it can reduce the stress associated with nerve dissection when a surgeon operates on a patient with a challenging anatomy or in cases of extensive surgery [7] but the main benefit remains its ability to guide the surgeon in cases of anatomical variations [45]. However the use of neuromonitoring in only selected cases does not allow adequate familiarity with the device and can lead to pitfalls.

In our experience, the use of this technique has decreased the stress of the surgeon, facilitated the identification of the nerve and given greater safety in the prosecution of the most difficult operations. These effects, however, are very difficult to quantify. Recurrent laryngeal nerve paresis occurrence diminishes the quality of life for a few weeks to months after thyroid surgery; so any improvement in this field is welcome [5]. Recurrent laryngeal nerve monitoring also allows for nerve function documentation before and after thyroid resection (by printing the electromyographic signal of evoked potentials), which is of great importance in an increasing number of litigation [5].

Conclusions

Visual nerve identification remains the gold standard of recurrent laryngeal nerve management in thyroid surgery. The technique of intraoperative neuromonitoring is safe, effective, and reliable in excluding postoperative recurrent laryngeal nerve palsy. Neuromonitoring helps to identify the recurrent laryngeal nerve, in particular in difficult cases, but it did not decrease recurrent laryngeal nerve injuries compared with visualization alone in this study. Future studies are warranted to evaluate the benefit of intraoperative neuromonitoring in thyroidectomy, especially in conditions in which the recurrent laryngeal nerve is at high risk of injury.

References

  1. Sanabria A, Silver CE, Suárez C, Shaha A, Khafif A, Owen RP, Rinaldo A, Ferlito A: Neuromonitoring of the laryngeal nerves in thyroid surgery: a critical appraisal of the literature. Eur Arch Otorhinolaryngol. 2013, 270: 2383-2395.

    Article  PubMed  Google Scholar 

  2. Chiang FY, Lee KW, Chen HC, Chen HY, Lu IC, Kuo WR, Hsieh MC, Wu CW: Standardization of intraoperative neuromonitoring of recurrent laryngeal nerve in thyroid operation. World J Surg. 2010, 34: 223-229.

    Article  PubMed  Google Scholar 

  3. Dralle H, Sekulla C, Haerting J, Timmermann W, Neumann HJ, Kruse E, Grond S, Mühlig HP, Richter C, Voss J, Thomusch O, Lippert H, Gastinger I, Brauckhoff M, Gimm O: Risk factors of paralysis and functional outcome after recurrent laryngeal nerve monitoring in thyroid surgery. Surgery. 2004, 136: 1310-1322.

    Article  PubMed  Google Scholar 

  4. Calò PG, Erdas E, Medas F, Pisano G, Barbarossa M, Pomata M, Nicolosi A: Late bleeding after total thyroidectomy: report of two cases occurring 13 days after operation. Clin Med Insights Case Rep. 2013, 6: 165-170.

    Article  PubMed  PubMed Central  Google Scholar 

  5. Barczyński M, Konturek A, Cichoń S: Randomized clinical trial of visualization versus neuromonitoring of recurrent laryngeal nerves during thyroidectomy. Br J Surg. 2009, 96: 240-246.

    Article  PubMed  Google Scholar 

  6. Dralle H, Sekulla C, Lorenz K, Brauckhoff M, Machens A, the German IONM Study Group: Intraoperative monitoring of the recurrent laryngeal nerve in thyroid surgery. World J Surg. 2008, 32: 1358-1366.

    Article  PubMed  CAS  Google Scholar 

  7. Duclos A, Lifante JC, Ducarroz S, Soardo P, Colin C, Peix JL: Influence of intraoperative neuromonitoring on surgeons’ technique during thyroidectomy. World J Surg. 2011, 35: 773-778.

    Article  PubMed  Google Scholar 

  8. Dionigi G, Dionigi R: Standardization of intraoperative neuromonitoring of recurrent laryngeal nerve in thyroid operation: to the editor. World J Surg. 2010, 34: 2794-2795.

    Article  PubMed  CAS  Google Scholar 

  9. Hemmerling TM, Schmidt J, Bosert C, Jacobi KE, Klein P: Intraoperative monitoring of the recurrent laryngeal nerve in 151 consecutive patients undergoing thyroid surgery. Anesth Analg. 2001, 93: 396-399.

    PubMed  CAS  Google Scholar 

  10. Horne SK, Gal TJ, Brennan JA: Prevalence and patterns of intraoperative nerve monitoring for thyroidectomy. Otolaryngol Head Neck Surg. 2007, 136: 952-956.

    Article  PubMed  Google Scholar 

  11. Pardal-Refoyo JL: Usefulness of neuromonitoring in thyroid surgery. Acta Otorrinolaringol Esp. 2012, 63: 355-363.

    Article  PubMed  Google Scholar 

  12. Terris DJ, Anderson SK, Watts TL, Chin E: Laryngeal nerve monitoring and minimally invasive thyroid surgery. Complementary Technologies. Arch Otolaryngol Head Neck Surg. 2007, 133: 1254-1257.

    Article  PubMed  Google Scholar 

  13. Thomusch O, Sekulla C, Walls G, Machens A, Dralle H: Intraoperative neuromonitoring of surgery for benign goiter. Am J Surg. 2002, 183: 673-678.

    Article  PubMed  Google Scholar 

  14. Zheng S, Xu Z, Wei Y, Zeng M, He J: Effect of intraoperative neuromonitoring on recurrent laryngeal nerve palsy rates after thyroid surgery – A meta-analysis. J Formos Med Assoc. 2013, 112: 463-472.

    Article  PubMed  Google Scholar 

  15. Angelos P: Recurrent laryngeal nerve monitoring: state of the art, ethical and legal issues. Surg Clin N Am. 2009, 89: 1157-1169.

    Article  PubMed  Google Scholar 

  16. Calò PG, Pisano G, Medas F, Tatti A, Tuveri M, Nicolosi A: Risk factors in reoperative thyroid surgery for recurrent goitre. Our experience. G Chir. 2012, 33: 335-338.

    PubMed  Google Scholar 

  17. Calò PG, Tatti A, Medas F, Petruzzo P, Pisano G, Nicolosi A: Forgotten goiter. Our experience and a review of the literature. Ann Ital Chir. 2012, 83: 487-490.

    PubMed  Google Scholar 

  18. Chan WF, Lo CY: Pitfalls of intraoperative neuromonitoring for predicting postoperative recurrent laryngeal nerve function during thyroidectomy. World J Surg. 2006, 30: 806-812.

    Article  PubMed  Google Scholar 

  19. Thomusch O, Sekulla C, Machens A, Neumann HJ, Timmermann W, Dralle H: Validity of intra-operative neuromonitoring signals in thyroid surgery. Langenbecks Arch Surg. 2004, 389: 499-503.

    Article  PubMed  Google Scholar 

  20. Domosławski P, Łukieńczuk T, Kaliszewski K, Sutkowski K, Wojczys R, Wojtczak B: Safety and current achievements in thyroid surgery with neuromonitoring. Adv Clin Exp Med. 2013, 22: 125-130.

    PubMed  Google Scholar 

  21. Chiang FY, Lu IC, Chen HC, Chen HY, Tsai CJ, Lee KW, Hsiao PJ, Wu CW: Intraoperative neuromonitoring for early localization and identification of recurrent laryngeal nerve during thyroid surgery. Kaohsiung J Med Sci. 2010, 26: 633-639.

    Article  PubMed  Google Scholar 

  22. Sturgeon C, Sturgeon T, Angelos P: Neuromonitoring in thyroid surgery: attitudes, usage patterns, and predictors of use among endocrine surgeons. World J Surg. 2009, 33: 417-425.

    Article  PubMed  Google Scholar 

  23. Chan WF, Lang BH, Lo CY: The role of intraoperative neuromonitoring of recurrent laryngeal nerve during thyroidectomy: a comparative study on 1000 nerves at risk. Surgery. 2006, 140: 866-872.

    Article  PubMed  Google Scholar 

  24. Chiang FY, Lu IC, Chen HC, Chen HY, Tsai CJ, Hsiao PJ, Lee KW, Wu CW: Anatomical variations of recurrent laryngeal nerve during thyroid surgery: how to identify and handle the variations with intraoperative neuromonitoring. Kaohsiung J Med Sci. 2010, 26: 575-583.

    Article  PubMed  Google Scholar 

  25. Loch-Wilkinson TJ, Stalberg PL, Sidhu SB, Sywak MS, Wilkinson JF, Delbridge LW: Nerve stimulation in thyroid surgery: is it really useful?. ANZ J Surg. 2007, 77: 377-380.

    Article  PubMed  Google Scholar 

  26. Sari S, Erbil Y, Sümer A, Agcaoglu O, Bayraktar A, Issever H, Ozarmagan S: Evaluation of recurrent laryngeal nerve monitoring in thyroid surgery. Int J Surg. 2010, 8: 474-478.

    Article  PubMed  Google Scholar 

  27. Chiang FY, Lu IC, Kuo WR, Lee KW, Chang NC, Wu CW: The mechanism of recurrent laryngeal nerve injury during thyroid surgery – The application of intraoperative neuromonitoring. Surgery. 2008, 143: 743-749.

    Article  PubMed  Google Scholar 

  28. Dionigi G, Barczynski M, Chiang FY, Dralle H, Duran-Poveda M, Iacobone M, Lombardi CP, Materazzi G, Mihai R, Randolph GW, Sitges-Serra A: Why monitor the recurrent laryngeal nerve in thyroid surgery?. J Endocrinol Invest. 2010, 33: 819-822.

    Article  PubMed  CAS  Google Scholar 

  29. Eisele DW: Intraoperative electrophysiologic monitoring of the recurrent laryngeal nerve. Laryngoscope. 1996, 106: 443-449.

    Article  PubMed  CAS  Google Scholar 

  30. Julien N, Mosnier I, Bozorg Grayeli A, Nys P, Ferrary E, Sterkers O: Intraoperative laryngeal nerve monitoring during thyroidectomy and parathyroidectomy: a prospective study. Eur Ann Otorhinolaryngol Head Neck Dis. 2012, 129: 69-76.

    Article  PubMed  CAS  Google Scholar 

  31. Angelos P: Ethical and medicolegal issues in neuromonitoring during thyroid and parathyroid surgery: a review of the recent literature. Curr Opin Oncol. 2012, 24: 16-21.

    Article  PubMed  Google Scholar 

  32. Calò PG, Pisano G, Medas F, Tatti A, Pittau MR, Demontis R, Favoriti P, Nicolosi A: Intraoperative recurrent laryngeal nerve monitoring in thyroid surgery: is it really useful?. Clin Ter. 2013, 164: e193-e198.

    PubMed  Google Scholar 

  33. Shindo M, Chheda NN: Incidence of vocal cord paralysis with and without recurrent laryngeal nerve monitoring during thyroidectomy. Arch Otolaryngol Head Neck Surg. 2007, 133: 481-485.

    Article  PubMed  Google Scholar 

  34. Cernea CR, Brandão LG, Brandão J: Neuromonitoring in thyroid surgery. Curr Opin Otolaryngol Head Neck Surg. 2012, 20: 125-129.

    Article  PubMed  Google Scholar 

  35. Ho Y, Carr MM, Goldenberg D: Trends in intraoperative neural monitoring for thyroid and parathyroid surgery amongst otolaryngologists and general surgeons. Eur Arch Otorhinolaryngol. 2013, 270: 2525-2530.

    Article  PubMed  Google Scholar 

  36. Randolph GW, Dralle H, with the International Intraoperative Monitoring Study Group: Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: international standards guidelines statement. Laryngoscope. 2010, 121: S1-S16.

    Article  Google Scholar 

  37. Dionigi G, Bacuzzi A, Boni L, Rausei S, Rovera F, Dionigi R: Visualization versus neuromonitoring of recurrent laryngeal nerves during thyroidectomy: what about the costs?. World J Surg. 2012, 36: 748-754.

    Article  PubMed  Google Scholar 

  38. Marrazzo A, Taormina P, David M, Riili I, Casà L, Noto A, Romano G, Marrazzo E, Buscemi G: Il carcinoma della tiroide: dalla diagnosi alla terapia. Chir Ital. 2008, 60: 685-695.

    PubMed  Google Scholar 

  39. Cirocchi R, Boselli C, Guarino S, Sanguinetti A, Trastulli S, Desiderio J, Santoro A, Rondelli F, Conzo G, Parmeggiani D, Noya G, De Toma G, Avenia N: Total thyroidectomy with ultrasonic dissector for cancer: multicentric experience. World J Surg Oncol. 2012, 10: 70.

    Article  PubMed  PubMed Central  Google Scholar 

  40. Calò PG, Tatti A, Farris S, Piga G, Malloci A, Nicolosi A: Il gozzo cervico-mediastinico: nostra esperienza. Ann Ital Chir. 2005, 76: 331-335.

    PubMed  Google Scholar 

  41. Yarbrough DE, Thompson GB, Kasperbauer JL, Harper CM, Grant CS: Intraoperative electromyographic monitoring of the recurrent laryngeal nerve in reoperative thyroid and parathyroid surgery. Surgery. 2004, 136: 1107-1115.

    Article  PubMed  Google Scholar 

  42. Calò PG, Tuveri M, Pisano G, Tatti A, Medas F, Donati M, Nicolosi A: Il gozzo recidivo. Nostra esperienza. Chir Ital. 2009, 61: 545-549.

    PubMed  Google Scholar 

  43. Conzo G, Pasquali D, Bellastella G, Esposito K, Carella C, De Bellis A, Docimo G, Klain M, Iorio S, Napolitano S, Palazzo A, Pizza A, Sinisi AA, Zampella E, Bellastella A, Santini L: Total thyroidectomy, without prophylactic central lymph node dissection, in the treatment of differentiated thyroid cancer Clinical retrospective study on 221 cases. Endocrine. 2013, 44: 419-425.

    Article  PubMed  CAS  Google Scholar 

  44. Calò PG, Pisano G, Medas F, Tatti A, Tuveri M, Nicolosi A: The use of harmonic scalpel in thyroid surgery. Our experience. Ann Ital Chir. 2012, 83: 7-12.

    PubMed  Google Scholar 

  45. Hermann M, Hellebart C, Freissmuth M: Neuromonitoring in thyroid surgery. Prospective evaluation of intraoperative electrophysiological responses for the prediction of recurrent laryngeal nerve injury. Ann Surg. 2004, 240: 9-17.

    Article  PubMed  PubMed Central  Google Scholar 

  46. Sanabria A, Ramirez A, Kowalski LP, Silver CE, Shaha AR, Owen RP, Suárez C, Khafif A, Rinaldo A, Ferlito A: Neuromonitoring in thyroidectomy: a meta-analysis of effectiveness from randomized controlled trials. Eur Arch Otorhinolaryngol. 2013, 270: 2175-2189.

    Article  PubMed  Google Scholar 

  47. Higgins TS, Gupta R, Ketcham AS, Sataloff RT, Wadsworth JT, Sinacori JT: Recurrent laryngeal nerve monitoring versus identification alone on post-thyroidectomy true vocal fold palsy: a meta-analysis. Laryngoscope. 2011, 121: 1009-1017.

    Article  PubMed  Google Scholar 

  48. Alesina PF, Rolfs T, Hommeltenberg S, Hinrichs J, Meier B, Mohmand W, Hofmeister S, Walz MK: Intraoperative neuromonitoring does not reduce the incidence of recurrent laryngeal nerve palsy in thyroid reoperations: results of a retrospective comparative analysis. World J Surg. 2012, 36: 1348-1353.

    Article  PubMed  Google Scholar 

  49. Dionigi G, Frattini F: Staged thyroidectomy: time to consider intraoperative neuromonitoring as standard of care. Thyroid. 2013, 23: 906-908.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Pietro Giorgio Calò.

Additional information

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

PGC conceived of the study and drafted the manuscript. GP carried out part of the operations and helped to draft the manuscript. FM participated in the design of the study and performed the statistical analysis. MRP participated in the design of the study and helped to draft the manuscript. LG worked on follow-up of patients and helped to draft the manuscript. RD participated in the design of the study and helped to draft the manuscript. AN participated in the design and coordination of the study and helped to draft the manuscript. All authors read and approved the final manuscript.

Rights and permissions

This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Calò, P.G., Pisano, G., Medas, F. et al. Identification alone versus intraoperative neuromonitoring of the recurrent laryngeal nerve during thyroid surgery: experience of 2034 consecutive patients. J of Otolaryngol - Head & Neck Surg 43, 16 (2014). https://doi.org/10.1186/1916-0216-43-16

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/1916-0216-43-16

Keywords